| Product |
Name |
Description |
P/N |
File |
Rev |
| Regenerative Drives |
Regenerative Drives and Common Bus |
The intent of this guide is to provide the reader with a good
understanding of regenerative ac and dc drives along with their use
in system applications |
RDCBAG0400
|
pdf |
n/a |
| ALL |
S-Ramp Accel/Decel Ramps - All CT Products |
Illustrates the dramatic positive effects that S-Ramps can have
on a drive system versus using standard linear ramps. This
Application Note is pertinent to the entire Control Techniques
Drive range |
CTAN120
|
pdf |
1.3 |
| ALL |
Programmable Time Delays |
Illustrates the dramatic positive effects that S-Ramps can have
on a drive system versus using standard linear ramps. This
Application Note is pertinent to the entire Control Techniques
Drive range |
CTAN122
|
pdf |
1.4 |
| ALL Mentor, Quantum, Unidrive & Commander SE |
Filtering for Digital Displays |
Filtering/Smoothing for Digital Displays - Applies to
Mentor/Quantum, Unidrive and Commander SE Products |
CTAN124
|
pdf |
1.3 |
| AC Drives |
Common Bus Connection of AC Drives |
Guidelines and Considerations for Common Bus Connection of AC
Drives |
CTAN127 |
pdf |
1.1 |
| ALL |
Driving External Relays |
Our drives use open collector transistor outputs that can be
used to drive control relays |
CTAN154 |
pdf |
1.5 |
| ALL |
Creating Custom & Power-Up Displays |
Customizing the drive's power up display |
CTAN159 |
pdf |
1.8 |
| ALL |
4-20ma Current Loop Control |
All of the current Control Techniques drives have the ability
to accept a 4 to 20 milliamp signal as a reference input |
CTAN160 |
pdf |
1.0 |
| ALL |
Power Factor Comparison for AC and DC Drives |
The displacement power factor is the ratio of the electrical
power to the applied voltage times the current at the fundamental
frequency (60Hz) |
CTAN176 |
pdf |
1.1 |
| ALL |
Dynamic Braking Resistor Selection Chart (Per Horsepower of
Load) |
For various load inertia and number of stops per time, based on
150% motor rated torque |
CTAN179 |
pdf |
1.1 |
| ALL |
Saving All Drive & CoProcessor Data |
CT Browser has the ability to upload not only Drive data but
also all parameter data |
CTAN186 |
pdf |
1.3 |
| UC |
UD70 Replacement |
Replacement of UD7X Co-Processor Module & Program |
CTAN211 |
pdf |
1.0 |
| ALL |
Universal Interface Kit |
This kit is used to facilitate 120vac
Interface to a wide variety of Control Techniques drives with 24vdc
logic-input circuits |
CTAN217 |
pdf |
1.0 |
| M2, Q3 |
Evaluating the contents of a Coprocessor |
Sometimes there is a need to examine our
co-processors to see if a co-processor contain an embeded program
and what the author name is etc. This app note and accompanying
program will permit you to determine co-processor
contents |
CTAN219
with CTAPI
no CTAPI |
pdf
zip
zip |
1.1 |
| UC, SE, M2 |
CTKP Security Code |
Security Code & Set-Up
also for VTC, UD70 & MD29 |
CTAN209 |
pdf |
1.1 |
| n/a |
Analog Meters |
Interfacing Analog Meters |
CTAN242 |
n/a |
n/a |
| ALL |
CTIU Power-Up Screen |
Creating a Power-Up Splash Screen with CTIU's |
CTAN245 |
pdf |
1.1 |
| ALL |
Creating CTIU Splash Screens
w/Maths |
Creating Splash Screens w/Maths with the
CTIU Operator Interface Unit |
CTAN248
CTIU file |
pdf
cmc |
1.0 |
| UC, SE, M2, Q3 |
Creating Drive Documentation |
Creating Proper Drive
Documentation |
CTAN258 |
pdf |
1.0 |
| ALL |
Relay Suppression |
Relay Suppression |
CTAN266 |
pdf |
1.0 |
| ALL |
Extra Digital I/O |
Need another digital input? |
CTAN275 |
pdf |
1.0 |
| SP, ST, GP20, M2, Q3 |
Dynamic Braking |
Dynamic Braking Sizing & Protection Methods |
CTAN291 |
pdf |
1.0 |